What was found
FOUND CRACK AT FS 461.00 PRESSURE FLOOR SKIN BL 0.00 (UNDER A/C DUCT). REPAIRED PRESSURE FLOOR SKIN AT FS 461.00 BL 0.00 IAW REO 601R-53-41-103.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CRACK AT FS 461.00 PRESSURE FLOOR SKIN BL 0.00 (UNDER A/C DUCT). REPAIRED PRESSURE FLOOR SKIN AT FS 461.00 BL 0.00 IAW REO 601R-53-41-103.