What was found
FLOOR SILL ANGLES FOUND TO BE CORRODED BEYOND SRM 53-41-45-01 LIMITS. FLOOR SILL ANGLES WERE REPAIRED IAW GREO 601R-53-41-666.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SILL ANGLES FOUND TO BE CORRODED BEYOND SRM 53-41-45-01 LIMITS. FLOOR SILL ANGLES WERE REPAIRED IAW GREO 601R-53-41-666.