As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND ON FLOORBEAM ATTACHMENT FITTING TO THE PRESSURE BULKHEAD AT FS 621.00 AND LBL 9.0. CORROSION FOUND TO BE BEYOND LIMITS IAW CRJ 200 SRM 53-61-43-02 AND 53-00-00-01. FABRICATED FLOORBEAM ATTACHMENT FITTING IAW CRJ 200 SRM 53-61-43-00, 51-21-11, 51-52-06 AND 51-25-16. INSTALLATION OF FABRICATED FLOORBEAM ATTACHMENT FITTING DONE IAW CRJ 200 SRM 51-42-21 AND 51-41-02.