What was found
ON 2C INSPECTION, THE FUSELAGE FLOOR SUPPORT STRUCTURE CENTER BUTT STRAP WAS FOUND TO BE CORRODED. THE PART WAS REPLACED PER SRM CHAPTER 51 STANDARD PRACTICES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON 2C INSPECTION, THE FUSELAGE FLOOR SUPPORT STRUCTURE CENTER BUTT STRAP WAS FOUND TO BE CORRODED. THE PART WAS REPLACED PER SRM CHAPTER 51 STANDARD PRACTICES.