What was found
ON 2C TAS K 313-01Z, FUSELAGE FRAME 52 CANTED FRAME, UPPER HALF, WAS FOUND DAMAGED BY ARCING OF THE APU GENERATOR WIRE TERMINALS BOLTED TO THE FRAME. THE FRAME UPPER HALF WAS REPLACED PER SRM CHAP 51 STANDARD PRACTICES AND THE APU FIREWALL WAS REPAIRED PER SRM 53-30-04, FIGURE 202.