What was found
UPON COMPLIANCE OF C TASK 35-09, THE PAX OXYGEN MASK IN THE LAVATORY FAILED TO DROP. INVESTIGATION FOUND THE OXYGEN MASK DOOR LATCH SOLENOID FAILED. THE SOLENOID WAS REPLACED WITH A NEW PART. SYSTEM TESTED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPON COMPLIANCE OF C TASK 35-09, THE PAX OXYGEN MASK IN THE LAVATORY FAILED TO DROP. INVESTIGATION FOUND THE OXYGEN MASK DOOR LATCH SOLENOID FAILED. THE SOLENOID WAS REPLACED WITH A NEW PART. SYSTEM TESTED OK.