DURING 2C INSPECTION TASK 5310-131/132 O1I, FOUND LEFT HAND FLOOR CROSSBEAM AT FRAME 20 TO BE CORRODED. REMOVED CORRODED CROSSBEAM AND INSTALLED SERV PART IAW EMB 120 SRM CHAPTER 51.