What was found
ON 1C TASK 35-09, THE OXYGEN MASKS AT ROW 9 FAILED TO DEPLOY. INVESTIGATION FOUND THE OXYGEN MASK DOOR SOLENOID TO BE SHORTED. THE SOLENOID WAS REPLACED WITH A NEW PART, OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON 1C TASK 35-09, THE OXYGEN MASKS AT ROW 9 FAILED TO DEPLOY. INVESTIGATION FOUND THE OXYGEN MASK DOOR SOLENOID TO BE SHORTED. THE SOLENOID WAS REPLACED WITH A NEW PART, OK FOR SERVICE.