DURING 2C INSPECTION, TASK 5310-131-01I REVEALED CROSSBEAM AT FRAME 20 TO BE CORRODED BEYOND EMBRAER CORROSION LIMITS. REMOVED CROSSBEAM AND INSTALLED SERVICEABLE CROSSBEAM USING EMBRAER 120 SRM STANDARD PRACTICES.