What was found
INTERMITTENT LEFT DUCT OVERHEAT LIGHT ON WITH NORMAL DUCT TEMPERATURE INDICATION. DETERMINED TO BE AN INDICATION PROBLEM. REPLACED THE 190 DEGREE AND 250 DEGREE SWITCHES IN THE AIR CONDITIONING DUCT/PLENUM. OPERATIONAL CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INTERMITTENT LEFT DUCT OVERHEAT LIGHT ON WITH NORMAL DUCT TEMPERATURE INDICATION. DETERMINED TO BE AN INDICATION PROBLEM. REPLACED THE 190 DEGREE AND 250 DEGREE SWITCHES IN THE AIR CONDITIONING DUCT/PLENUM. OPERATIONAL CHECK NORMAL.