What was found
DURING A SCHEDULED INSPECTION FOUND ELEVATOR TRIM CABLE FRAYED AT LEAST HALF WAY THROUGH. THIS CABLE IS A PART OF A LARGER CABLE ASSY, PN 6660003-1. THIS CABLE HAS BEEN A SUBJET OF SL, BUT THESE CABLES HAVE IN THE PAST AND CONTINUE TO FRAY PREMATURELY. A SERVICE CONDITION REPORT HAS BEEN FILED WITH MFG UNDER NR 585949.