What was found
EMERGENCY LIGHTS FROM DOOR 2 AFT ILLUMINATED. FOUND EMERGENCY CHG RT P11-N35 CIRCUIT BREAKER OPEN. RESET CIRCUIT BREAKER AND PERFORMED OPS TEST OF EMERGENCY LIGHTS IAW AMM 33-51-00-50. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS FROM DOOR 2 AFT ILLUMINATED. FOUND EMERGENCY CHG RT P11-N35 CIRCUIT BREAKER OPEN. RESET CIRCUIT BREAKER AND PERFORMED OPS TEST OF EMERGENCY LIGHTS IAW AMM 33-51-00-50. OK FOR SERVICE.