What was found
AFT ACCESSORY COMPT STA 1485 L9R CANTED FRAME FWD SIDE RAIN DRAIN PAN ATTACHMENT ANGLE IS CRACKED. R & R ATTACH ANGLE IAW SRM 51-10-4 AND 51-30-05. FABRICATED NEW ATTACH CLIP OUT OF .040 2024-T3 RECEIVED ON PO NO 0922117 IAW DAC DWG PL4967110 REVA. INSTALLED NEW ATTACH CLIP WET WITH HILOCKS IAW SRM 51-30-05.