What was found
DURING HMV, AFT CARGO STA1211 LONG 28R AND 29R FLOOR ATTACH ANGLE CORRODED. CORROSION OUT OF LIMITS REMOVED, FAB NEW ANGLE IAW DWG 5956705. INSTALLED NEW ANGLE IAW SRM 51-30-2,51-30-5. (DLM88101566)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HMV, AFT CARGO STA1211 LONG 28R AND 29R FLOOR ATTACH ANGLE CORRODED. CORROSION OUT OF LIMITS REMOVED, FAB NEW ANGLE IAW DWG 5956705. INSTALLED NEW ANGLE IAW SRM 51-30-2,51-30-5. (DLM88101566)