What was found
DURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT Y1732 BETWEEN FR 65 & FR 66. REPAIRED PER SRM 51-44-11, SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT Y1732 BETWEEN FR 65 & FR 66. REPAIRED PER SRM 51-44-11, SRM 51-42-11.