What was found
DURING M-CHECK FOUND CORROSION ON FLOORBEAM AT +Y254 BETWEEN FR 16 & FR 21. REPAIRED IAW SRM 51-44-11, SRM 51-42-11, ERA 484240-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M-CHECK FOUND CORROSION ON FLOORBEAM AT +Y254 BETWEEN FR 16 & FR 21. REPAIRED IAW SRM 51-44-11, SRM 51-42-11, ERA 484240-14.