What was found
CORROSION ON CABIN FLOORBEAM UPPER CHORD AT STA 365 FROM RBL 63-BL'0'. BLENDED AREA DIM. L=5' W=2" D=.060" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, REMOVED OLD REPAIR IAW SRM 51-40-02. FAB, LOCATED, & DRILLED T-CHORD BEAM IAW SRM 51-40-05 & 53-00-51, INSTALLED REPAIR UPPER CHORD AT STA 365RBL 0 TO RBL 63 IAW SRM 51-40-02 & SRM 53-00-51 REPAIR 3. RII COMPLETED.