What was found
LT MLG TRAPE PANEL LOWER ATTACH ANGLE CRACKED. RII: Y REMOVED ATTACH ANGLE IAW SRM 51-30-1 AND 51-30-2. FABRICATED NEW ANGLE IAW SRM 51-10-4. INSTALLED IAW SRM 51-30-5. P-205 REQUIRED INSP COMPLETED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT MLG TRAPE PANEL LOWER ATTACH ANGLE CRACKED. RII: Y REMOVED ATTACH ANGLE IAW SRM 51-30-1 AND 51-30-2. FABRICATED NEW ANGLE IAW SRM 51-10-4. INSTALLED IAW SRM 51-30-5. P-205 REQUIRED INSP COMPLETED.