What was found
DURING M-CHECK FOUND 6 ELONGATED HOLES ON RT MAIN CABIN FLOORBEAM WEB AT BS 712. REPAIRED IAW DWG 9923410, SRM 51-30-5 & SRM 51-30-2 PAGE 205.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M-CHECK FOUND 6 ELONGATED HOLES ON RT MAIN CABIN FLOORBEAM WEB AT BS 712. REPAIRED IAW DWG 9923410, SRM 51-30-5 & SRM 51-30-2 PAGE 205.