What was found
DURING M-CHECK FOUND PREVIOUS REPAIR DISBONDED AND CRACKS MIGRATED BEYOND STOP DRILLS ON FLOOR PANEL 72. REPAIRED PER SRM 53-05 FIGURE 1 PAGE 10 & SRM 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M-CHECK FOUND PREVIOUS REPAIR DISBONDED AND CRACKS MIGRATED BEYOND STOP DRILLS ON FLOOR PANEL 72. REPAIRED PER SRM 53-05 FIGURE 1 PAGE 10 & SRM 51-10-3.