What was found
DURING M CHECK FOUND AFT PRESSURE BULKHEAD DOOR JAMB FRAME UPPER FRAME FLANGE HAD 2 MISLOCATED HOLES. REPAIRED PER SRM 51-70-5 FIGURE 1, SRM 51-10-4, SRM 51-10-3 DWG 5917463 REV N, SRM 51-30-5, SRM 51-20-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M CHECK FOUND AFT PRESSURE BULKHEAD DOOR JAMB FRAME UPPER FRAME FLANGE HAD 2 MISLOCATED HOLES. REPAIRED PER SRM 51-70-5 FIGURE 1, SRM 51-10-4, SRM 51-10-3 DWG 5917463 REV N, SRM 51-30-5, SRM 51-20-0.