What was found
FWD CABIN FLOORBEAM +Y254 BET FR 24 AND FR 25 CRACKED. TRIMMED OUT CRACKED AREA DIM: W=1" X L=3.470" IAW SRM 53-00-14 FIG 204. FABRICATED DOUBLER FROM 7075T6.063 BATCH 1502238. FABRICATED FILLER REPAIR FROM 7075T6.063 BATCH 1766127 IAW SRM 53-00-14 FIG 204. TREATED AND PRIMED DOUBLER & FILLER REPAIR IAW SRM 51-21-11. PAINTED TOPCOAT DOUBLER AND FILLER REPAIR IAW SRM 51-75-12. INSTALLED DOUBLER AND FILLER REPAIR SRM 51-42-11 AND 53-00-14 FIG 204.