What was found
MEDICAL PERSONNEL ATTEMPTED TO ENTER THROUGH THE AFT AIRSTRAIRS. FLIGHT ATTENDANT DID NOT PROPERLY DISARM THE DOOR AND WHEN EMT TRIED TO OPEN DOOR, THE TAIL CONE SEPARATED BUT THE EMERGENCY EVACUATION SLIDE DID NOT DEPLOY. MAINTENANCE FOUND TAIL CONE RELEASE MECHANISM PIN MISSING. RELEASE MECHANISM WAS REPLACED PER AMM 53-53-02-201. TAIL CONE RELEASE CAM WAS REMOVED, INSPECTED, AND RE-INSTALLED PER AMM 53-53-02. ORIGINAL SLIDE WAS RE-INSTALLED PER OPN 7915 AMM 25-62-01-201 RII COMPLETED BY QC1984. (2010-D1318)