What was found
DURING M-CHECK FOUND FOWARD CARGO COMPARTMENT, LT SIDE, STATION 522, VERTICAL STRUT CRACKED, AT LOWER AFT I/B CORNER. STOP DRILLED CRACK IAW DC-9 SRM 53-01 FIG 2. NDT VERIFIED CRACK CONTAINMENT IAW NDT SPM 06-10-01 .001 FABBED .025 7075T6 P.O.1022687 TREATED, PRIMED AND INSTALLED IAW DC-9 SRM 53-01 FIG 2 51-10-3 TABLE 1 51-30-2,51-30-5.