What was found
DURING M-CHECK FOUND MAIN PASSENGER CABIN FLOOR PANEL 102C HAS CORROSION TOP AND BOTTOM AROUND FASTENER HOLES. LOCATED, DRILLED AND DEBURRED FASTENER HOLES IN NEW FLOOR P/N 09-5300-3-3431 IAW DC9 SRM 51-10-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M-CHECK FOUND MAIN PASSENGER CABIN FLOOR PANEL 102C HAS CORROSION TOP AND BOTTOM AROUND FASTENER HOLES. LOCATED, DRILLED AND DEBURRED FASTENER HOLES IN NEW FLOOR P/N 09-5300-3-3431 IAW DC9 SRM 51-10-4.