What was found
DURING M-CHECK FOUND MAIN CABIN STA 160 TO 200, LBL 44 FLOOR SUPPORT HAS CORROSION. FLOOR SUPPORT STA 160-200 LBL ORIG MAT .060 CORRODED BEYOND LIMITS. FAB NEW SUPPORT USING PN 60-25767075T6511, PO 216ND946 LOCATED, DRILLED, TRIMMED, DEBURRED, TREAT, PRIMED AND INSTALLED IAW SRM 51-10-2, 51-10-3, 51-30-5, 51-10-1, FIG 22 PG.72.