What was found
DURING L-CHECK FOUND LOWER FUSELAGE AT STA 207.1, APPROX 36" BELOW STR 20R LAP JOINT 1EA FASTENER AND ADJACENT SKIN HAS LIGHTNING STRIKE. REMOVED 1 EA FASTENER FUSELAGE AT 207.1 IAW SRM 51-40-02, HFEC IAW NTM 51-00-13 PT6, NO CRACK INDICATION NOTED. INCREASED HOLE DIAMETER FROM 0.195 TO 0.228 IAW SRM 53-00-01, REF6, SHEET 2, STEP 3A. SKIN DAMAGE ADJACENT TO EACH HOLE REMOVED, HFEC IAW NTM 51-00-16, PT6, NO DEFECTS NOTED. TREATED, PRIMED HOLE IAW SRM 51-20-01. INSTALLED 1EA FASTNER IAW SRM 51-40-02. TOP COATED AREA IAW SRM 51-21-10.