What was found
DURING M-CHECK FOUND MAIN CABIN STA 200 LBL 1 TO LBL 20 FLOOR SUPPORT HAS CORROSION. FLOOR SUPPORT FOUND TO BE OUT OF LIMITS IAW DC-9 SRM 53-01 FIG.1. REMOVED FLOOR SUPPORT IAW DC-9 SRM 51-30-5. FABRICATED NEW FLOOR SUPPORT FROM EXTRUSION P/N S2652479 7075-T6 PO#1021992. TRIMMED,LOCATED, DRILLED AND DEBURRED IAW DC-9 SRM 51-10-4,5 1-10-2, 51-10-1 FIG 27. TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-3, 51-30-5.