What was found
DURING M-CHECK FOUND MAIN CABIN STA 180 RBL 38 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW DC9 SRM 51-10-3. ORG MAT .050 REMOVED.029 REMAINING .021 FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-01 FIG 1. REMOVED FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-2, 51-10-4, 51-10-3, 51-30-5 AND DOUGLAS DRAWING 9923484.