What was found
DURING M-CHECK FOUND MAIN CABIN STA 200 TO 218 AND BL 0 TO LBL 20 SUB-FLOOR CHAFED SEVERAL PLACES. BLENDED CHAFE AREAS 1"X 2" 4 EA PLACES.ORIGINAL .020 REMOVED.008 REMAINING .012.FOUND TO BE OUT OF LIMITS FABRICATED AND INSTALLED FILLER .020 7075-T6 PO 10225 7 REPAIR DOUBLER FROM .025 7075-T6 IAW DC-9 SRM 53-01 FIG 1, 51-10-2, 51-10-4, 51-20-4 FIG 2, 51-10-3, 51-30-5 SRP 53-20-3.