What was found
DURING M-CHECK FOUND MAIN CABIN METAL FLOOR PANEL 71 HAS DENT. CUT OUT DAMAGE PER DC9 SRM 53-01. ALODINED AND PRIMED IAW DC9 SRM 51-10-3. INSTALLED DOUBLER AND FILLER IAW DC9 SRM 53-01 FIG 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M-CHECK FOUND MAIN CABIN METAL FLOOR PANEL 71 HAS DENT. CUT OUT DAMAGE PER DC9 SRM 53-01. ALODINED AND PRIMED IAW DC9 SRM 51-10-3. INSTALLED DOUBLER AND FILLER IAW DC9 SRM 53-01 FIG 4.