What was found
DURING M-CHECK FOUND AFT ACC COMPT STA 1209 AT L12L FRAME SHEAR ANGLE CRACKED. REMOVED 5 EA ANGLES AND CRACKED SHEAR TIE BETWEEN LONGERON 10 AND 14 RH STA 1209. FABRICATED, LOCATED, DRILLED NEW SHEAR TIE IAW SRM 51-13-4, FIG 1 AND 51-60-00 FIG.1, 51-30-2, 51-30-5. INSTALLED NEW SHEAR TIE AND ANGLES IAW SRM 51-30-5-51-30-2.