As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING M-CHECK FOUND RIGHT PYLON INTERIOR WEB CRACKED IN LOWER O/B RADIUS JUST AFT OF 8TH STAGE DUCT. STOP DRILL CONTAINED CRACK IAW DC9 NDT SPM 06-10-01.001 FABRICATED AND INSTALLED 2EA. DOUBLERS AND 1EA FILLER FROM P/N 020X48X144 2024T3 S/N 0920335 & P/N .025X48X144 2024T3 S/N 1022631 IAW DC9 SRM 54-01 EXAMPLE D & DC9 SRM 51-30-5. P226.