What was found
DURING "H" CHECK FOUND FLOOR PANEL 261FF CORRODED. REPLACED FLOOR PANEL. WORK ACCOMPLISHED IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING "H" CHECK FOUND FLOOR PANEL 261FF CORRODED. REPLACED FLOOR PANEL. WORK ACCOMPLISHED IAW SRM 51-72-11.