What was found
DURING M-CHECK, FOUND CABIN FLOOR PANEL 78 CRACKED CUTOUT DAMAGE 2.5"X2" IAW SRM 53-05, FIG 1. FABRICATED FILLER AND DOUBLER IAW SRM 53-05, FIG 1. TREATED AND PRIMED INSTALLED FILLER AND DOUBLER IAW SRM 53-05, FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M-CHECK, FOUND CABIN FLOOR PANEL 78 CRACKED CUTOUT DAMAGE 2.5"X2" IAW SRM 53-05, FIG 1. FABRICATED FILLER AND DOUBLER IAW SRM 53-05, FIG 1. TREATED AND PRIMED INSTALLED FILLER AND DOUBLER IAW SRM 53-05, FIG 1.