What was found
DURING M-CHECK, FOUND MAIN CABIN RT STA 832 OTBD FLOOR PANEL ZEE ANGLE SUPPORT BROKEN ON END. REMOVED 26" SECTION OF ZEE ANGLE. FABRICATED 1EA ZEE ANGLE SPLICE IAW SRM 53-13-3 FIG 13, SHEET 1 & 2, 51-10-1 FIG 1, SHEET 2 AND 51-10-2. INSTALLED ZEE ANGLE AND SPLICE IAW SRM 51-10-4, 51-30-2, AND 51-30-5.