Service difficulty report · Floor Support · Doug DC951

Difficulty date
December 3, 2010
Submitted
December 6, 2010
Operation
Air carrier
Aircraft
N773NC
Make and model
Doug DC951
Aircraft serial
47775
Aircraft time
73,440 hours, 70,600 cycles
Engine
Pwa JT8D9
Part
Floor Support
Condition
Corroded
Location
Bs 160-200
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING M-CHECK, FOUND MAIN PASSENGER CABIN STA 160-200, RBL 44, FLOOR PANEL SUPPORT HAD CORROSION. REMOVED CORROSION ON FLOOR SUPPORT MAIN CABIN STA 160-200, RBL 44 IAW SRM 53-01, FIG 1, ORIGINAL THICKNESS .060 IAW SRM 51-13-1. MATERIAL REMOVED .030 MATERIAL REMAINING .030 FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1. FABRICATED NEW FLOOR SUPPORT IAW SRM 53-13-1. TRIMMED DRILLED DEBURRED NEW FLOOR SUPPORT IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED FLOOR SUPPORT IAW SRM 51-30-5.