DURING "H" CHECK FOUND FLOORBEAM, Y765 AT FR66 CORRODED. INSTALLED FLOORBEAM SPLICE. WORK ACCOMPLISHED IAW SRM 53-41-15, SRM 51-42-11, AND SRM 51-44-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING "H" CHECK FOUND FLOORBEAM, Y765 AT FR66 CORRODED. INSTALLED FLOORBEAM SPLICE. WORK ACCOMPLISHED IAW SRM 53-41-15, SRM 51-42-11, AND SRM 51-44-11.