What was found
DURING M-CHECK FOUND FWD CABIN FLOOR SUPPORT AT LBL 67 PREVIOUS REPAIR BETWEEN STN 430 TO STN 450 CORRODED AT 3 LOCATIONS. FOUND TO BE OUT OF LIMITS IAW SRM 53-30-13 FIG 101, DET 8, REMOVED FLOOR SUPPORT IAW SRM 51-40-02, FABRICATED NEW PART LOCATED & DRILLED IAW SRM 51-40-05, TREATED & PRIMED IAW SRM 51-20-01, PAINTED IAW AMM 51-21-00, INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-02.