What was found
WHILE ACCOMPLISHING A SID INSP OF PSE 53.09.028, IAW AD2006-21-06, EM5330-01148-01B, A 1.8" LONG CRACK WAS FOUND IN THE SKIN, STA 1247, L1 TO L2R. WORK IAW ER/A 482375-14AD AS FOLLOWS: SECTION I ACCOMPLISHED DURING MX - DEC 2010, SECTION II - ON OR BEFORE 24MOS AFTER SECTION I - TBD PENDING DAMAGE TOLERANCE EVALUATION ASSOCIATED AA 5330-01148 ADDED FOR AC 0853 ASSOCIATED ER/A 13-482375 ADDED FOR AC 0853.