What was found
DURING M-CHECK FOUND MAIN CABIN STA 237, LBL 24 TO LBL 42 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION STA 237, LBL24 TO LBL42 OUT OF LIMITS IAW SRM 53-01, FIG 1. REMOVED FLOOR SUPPORT IAW SRM 51-30-2. FABRICATED FLOOR SUPPORT IAW SRM 53-13-2 FIG 4, 51-10-4 TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED IAW SRM 51-30-2 LOCATED AND DRILLED HOLES IN FLOOR SUPPORT FOR FLOOR PANEL IAW SRM 51-10-4.