What was found
DURING MX CORROSION WAS FOUND COMMON TO THE FUSELAGE CREASE BEAM AT STA 1630, WL 208. THE CORRODED AREA OF THE CREASE BEAM WAS CUTOUT AND A REPAIR WAS INSTALLED IAW SECTION OF ER/A 13-487261-14. THE REPAIR IAW SECTION I IS STATICALLY APPROVED FOR 24 MONTHS AFTER 13DEC10 PENDING DTA. OBTAIN DTA APPROVAL OF THE SECT I REPAIR BY 13DEC12 OR REMOVE THE ACFT FROM REVENUE SERVICE. IF THIS L/P IS NOT REVISED BY 13OCT12, CONTACT LIAISON ENGINEERING.