What was found
DURING M-CHECK FOUND FWD CABIN FLOORBEAM, STN 365 PREVIOUS REPAIR FROM LBL 15 TO RBL 64 CORRODED AT SEVERAL LOCATIONS AS MARKED. BLENDED AREA ON FLOORBEAM FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101. FABRICATED NEW UPPER CHORD TREATED AND PRIMED NEW UPPER CHORD IAW SRM 51-20-01. APPLIED TOPCOAT TO UPPER CHORD IAW SRM 51-21-00. INSTALLED FRAME SPLICE IAW SRM 51-40-02. INSTALLED SUPPORT ANGLE AT RBL 60, STA 365 IAW SRM 51-40-02. INSTALLED SUPPORT ANGLE RBL 24.75, STA 365 IAW SRM 51-40-02. INSTALLED (2EA) SUPPORT BRACKETS AT RBL 45.5 STA 365 IAW SRM 51-40-02. INSTALLED SUPPORT CHANNEL STA 345-365, RBL 24. INSTALLED UPPER FLOORBEAM CAP IAW SRM 53-00-51.