What was found
DURING M-CHECK FOUND LAVATORY, STA 1139, RBL 22 FLOOR PANEL SUPPORT HAS CORROSION. REMOVED FLOOR PANEL SUPPORT IN LAV AREA STA 1139, RBL 22 IAW SRM 51-30-2. FABRICATED NEW FLOOR PANEL SUPPORT IAW DWG 94FS481223 TREATED, PRIMED AND TOPCOATED IAW SRM 51-10-3, INSTALLED FLOOR PANEL SUPPORT IAW SRM 51-10-4, 51-10-5.