What was found
DURING M-CHECK, FOUND MAIN CABIN FLOOR PANEL NR32 GOUGED 2 PLACES IN FLOOR PANEL. BLENDED GOUGES IAW SRM 53-01, FIG 1. MATERIAL FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1 CUTOUT DAMAGED SECTION OF CHANNEL IAW SRM 53-05, FIG 1. FABBED 2EA CHANNELS IAW SRM 53-05, FIG 1. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED 2EA CHANNEL IAW 51-30-2.