What was found
DURING M-CHECK, FOUND MAIN CABIN FLOOR SUPPORT WEB AT BS 753 RBL 40 IS CRACKED AT UPPER RIVET. HFEC INSP IAW NDT SPM 06-10-01.001 VERIFIED CRACK CONTAINED BY FASTENER HOLE. FABRICATED REPAIR DOUBLER IAW SRM 53-01, FIG 2 AND SRM 53-13-3, FIG 1. INSTALLED DOUBLER IAW SRM 53-01, FIG 2 AND SRM 51-30-5, PG 12 PAR 7B.