What was found
DURING M-CHECK, FOUND HOLE IN MAIN CABIN FLOOR PANEL 32. CUTOUT DAMAGE IAW 53-01, FIG 4. NDT VERIFIED DAMAGE WAS CONTAINED IAW NDT SPM 06-10-01.001. FABRICATED DOUBLER AND FILLER IAW SRM 53-01, FIG 4. TREATED AND PRIMED DOUBLER AND FILLER IAW SRM 51-10-3. INSTALLED DOUBLER AND FILLER IAW 53-01, FIG 4.