What was found
DURING M”-CHECK, FOUND MAIN CABIN FLOOR PANEL NR74 HAS CRACK ON END. CUTOUT DAMAGED AREA IAW SRM 51-70-4. FABRICATED AND INSTALLED FILLER FABRICATED DOUBLER IAW SRM 51-70-4. INSTALLED FILLER AND DOUBLER IAW SRM 51-30-2, 51-70-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M”-CHECK, FOUND MAIN CABIN FLOOR PANEL NR74 HAS CRACK ON END. CUTOUT DAMAGED AREA IAW SRM 51-70-4. FABRICATED AND INSTALLED FILLER FABRICATED DOUBLER IAW SRM 51-70-4. INSTALLED FILLER AND DOUBLER IAW SRM 51-30-2, 51-70-4.