What was found
DURING M-CHECK, FOUND MAIN PASSENGER CABIN BETWEEN STA 200-218, RBL 18 FLOOR PANEL SUPPORT HAS CORROSION. REMOVED FLOOR PANEL SUPPORT IAW SRM 51-30-0. REMOVED CORROSION IAW SRM 51-10-3. OUT OF LIMITS IAW SRM 53-01, FIG 1. RECEIVED IEA RAW MATERIAL IAW SRM 51-10-2 LOCATED, DRILLED, DEBURRED IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED FLOOR SUPPORT FOR PANEL IAW SRM 51-30-5.