What was found
DURING H-CHECK FOUND FLOOR PANEL NR 20 IS CRACKED IN 3 PLACES AND HAS CORROSION ON TOP AND BOTTOM OF PANEL. REPAIRED IAW SRM 51-10-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING H-CHECK FOUND FLOOR PANEL NR 20 IS CRACKED IN 3 PLACES AND HAS CORROSION ON TOP AND BOTTOM OF PANEL. REPAIRED IAW SRM 51-10-4.